Weighing and portable platforms for every environment, application and accuracy requirement. Wheel or axle weighing in order to check the weight and the overload of any vehicle. Portable platforms easy to move and install specially indicated to create weighing station in any place. High flexibility: weight vehicles, from the small size like cars, carts, etc.. to the big size like truck, tractors, etc… Portable units in comfortable ABS case with single or mutliple channel, in order to connect one or more load cells.

Overload protection for lifting baskets


Zoom Click to enlarge image

Weighing Systems KIT Cestello Weighing Systems KIT Cestello Schema

Technical Specifications

Operating temperature-20 / +70°C (4 / 158°F)
Protection levelIP 67
Power supply load cellsPower supply 24 V direct current, output 4-20 mA
Linearity0,03 % of full scale
Temperature deviation0,002 % of full scale/°C
Dimensionsjunction box 125x80x40 mm without cable gland
Cell connection40 cm
Load cells materialStainless steel
Load cells capacity750 kg
Connection cable5 m – 4 x 0,25 (shield not connected to the load cell body) – 2 cables (black and grey)
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means